索引超出了数组界限。 文章摘要
|本期目录/Table of Contents|

[1]万青 张奇.心脏磁共振在经导管主动脉瓣置入术中的应用[J].国际心血管病杂志,2019,04:198-201.
点击复制

心脏磁共振在经导管主动脉瓣置入术中的应用(PDF)

《国际心血管病杂志》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2019年04期
页码:
198-201
栏目:
综述
出版日期:
2019-09-27

文章信息/Info

Title:
-
作者:
万青 张奇
200120 上海,同济大学附属东方医院心内科
Author(s):
-
关键词:
主动脉瓣狭窄 经导管主动脉瓣置入术 心脏磁共振
Keywords:
-
分类号:
-
DOI:
10.3969/j.issn.1673-6583.2019.04.002
文献标识码:
-
摘要:
主动脉瓣狭窄是常见的心血管疾病,患者一旦出现临床症状,病情进展迅速。经导管主动脉瓣置入术作为治疗主动脉瓣狭窄的新兴介入技术,已在外科手术高危及禁忌人群中开展。因经导管主动脉瓣置入术为非直视手术,精确的影像学评估尤为重要。心脏磁共振具有高时间、空间分辨率和高组织对比度优势,该文介绍心脏磁共振不同序列在经导管主动脉瓣置入术中的应用。
Abstract:
-

参考文献/References

[ 1 ] Joseph J, Naqvi SY, Giri J, et al. Aortic stenosis: pathophysiology, diagnosis, and therapy[J]. Am J Med, 2017, 130(3):253-263.
[ 2 ] Miller JG, Li M, Mazilu D, et al. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement[J]. J Thorac Cardiovasc Surg, 2016, 151(5):1269-1277.
[ 3 ] Baumgartner H, Falk V, Bax JJ, et al. 2017 ESC/EACTS Guidelines for the management of vavular heart disease: the task force for the management of valvular heart disease of the Europan Society of Cardiology(ESC)and the European Association for Cardio-Thoracic Surgery(EACTS)[J]. Eur Heart J, 2017, 52(4):832.
[ 4 ] Otto CM, Kumbhani DJ, Alexander KP, et al. 2017 ACC expert consensus decision pathway for transcatheter aortic valve replacement in the management of adults with aortic stenosis: a report of the American College of Cardiology task force on clinical expert consensus documents[J]. J Am Coll Cardiol, 2017, 69(10):1313-1346.
[ 5 ] Gulsin GS, Singh A, McCann GP. Cardiovascular magnetic resonance in the evaluation of heart valve disease[J]. BMC Med Imaging, 2017, 17(1):67.
[ 6 ] Steffens JC, Bourne MW, Sakuma H, et al. Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging[J]. Circulation, 1994, 90(2):937-943.
[ 7 ] Kupfahl C, Honold M, Meinhardt G, et al. Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques[J]. Heart, 2004, 90(8):893-901.
[ 8 ] Pouleur AC, le Polain de Waroux JB, Pasquet A, et al. Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography[J]. Radiology, 2007, 244(3):745-754.
[ 9 ] Phan K, Wong S, Phan S, et al. Transcatheter aortic valve implantation(TAVI)in patients with bicuspid aortic valve stenosis-systematic review and meta-analysis[J]. Heart Lung Circ, 2015, 24(7):649-659.
[10] Jabbour A, Ismail TF, Moat N, et al. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography[J]. J Am Coll Cardiol, 2011, 58(21):2165-2173.
[11] Renker M, Varga-Szemes A, Schoepf UJ, et al. A non-contrast self-navigated 3-dimensional MR technique for aortic root and vascular access route assessment in the context of transcatheter aortic valve replacement: proof of concept[J]. Eur Radiol, 2016, 26(4):951-958.
[12] 中国医师协会心血管内科医师分会结构性心脏病专业委员会,中华医学会心血管病学分会结构性心脏病学组. 经导管主动脉瓣置换术中国专家共识[J]. 中国介入心脏病学杂志, 2015, 23(12):661-667.
[13] Gonzalez JA, Kramer CM. Role of imaging techniques for diagnosis, prognosis and management of heart failure patients: cardiac magnetic resonance[J]. Curr Heart Fail Rep, 2015, 12(4):276-283.
[14] Fairbairn TA, Motwani M, Greenwood JP, et al. CMR for the diagnosis of right heart disease[J]. JACC Cardiovasc Imaging, 2012, 5(2):227-229.
[15] Chin CWL, Everett RJ, Kwiecinski J, et al. Myocardial fibrosis and cardiac decompensation in aortic stenosis[J]. JACC Cardiovasc Imaging, 2017, 10(11):1320-1333.
[16] Barone-Rochette G, Piérard S, De Meester de Ravenstein C, et al. Prognostic significance of LGE by CMR in aortic stenosis patients undergoing valve replacement[J]. J Am Coll Cardiol, 2014, 64(2):144-154.
[17] Haaf P, Garg P, Messroghli DR, et al. Cardiac T1 mapping and extracellular volume(ECV)in clinical practice: a comprehensive review[J]. J Cardiovasc Magn Reson, 2016, 18(1):89.
[18] Fehrmann A, Treutlein M, Rudolph T, et al. Myocardial T1 and T2 mapping in severe aortic stenosis: potential novel insights into the pathophysiology of myocardial remodelling[J]. Eur J Radiol, 2018, 107(1):76-83.
[19] Nadjiri J, Nieberler H, Hendrich E, et al. Prognostic value of T1-mapping in TAVR patients: extra-cellular volume as a possible predictor for peri-and post-TAVR adverse events[J]. Int J Cardiovasc Imaging, 2016, 32(11):1625-1633.
[20] Kahlert P, Parohl N, Albert J, et al. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine[J]. J Cardiovasc Magn Reson, 2012, 14(1):21.
[21] Abdel-Wahab M, Abdelghani M, Miyazaki Y, et al. A novel angiographic quantification of aortic regurgitation after TAVR provides an accurate estimation of regurgitation fraction derived from cardiac magnetic resonance imaging[J]. JACC Cardiovasc Interv, 2018, 11(3):287-297.
[22] Kodali S, Hahn R, Williams M, et al. Impact of paravalvular leak following transcatheter aortic valve replacement on one-year mortality: analysis of the combined PARTNER cohorts[J]. Eur Heart J, 2013, 34(Suppl 1):2584.
[23] Crouch G, Tully PJ, Bennetts J, et al. Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement[J]. J Cardiovasc Magn Reson, 2015, 17(1):32.
[24] Hartlage GR, Babaliaros VC, Thourani VH, et al. The role of cardiovascular magnetic resonance in stratifying paravalvular leak severity after transcatheter aortic valve replacement: an observational outcome study[J]. J Cardiovasc Magn Reson, 2014, 16(1):93.
[25] Mack MJ, Leon MB, Smith CR, et al. 5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis(PARTNER 1): a randomised controlled trial[J]. Lancet, 2015, 385(9986):2477-2484.
[26] Rodés-Cabau J, Gutiérrez M, Bagur R, et al. Incidence, predictive factors, and prognostic value of myocardial injury following uncomplicated transcatheter aortic valve implantation[J]. J Am Coll Cardiol, 2011, 57(20):1988-1999.
[27] Kim WK, Rolf A, Liebetrau C, et al. Detection of myocardial injury by CMR after transcatheter aortic valve replacement[J]. J Am Coll Cardiol, 2014, 64(4):349-357.
[28] Truong VT, Safdar KS, Kalra DK, et al. Cardiac magnetic resonance tissue tracking in right ventricle: feasibility and normal values[J]. Magn Reson Imaging, 2017, 38(1):189-195.
[29] Kearney LG, Ord M, Matalanis G, et al. Global longitudinal strain is a strong independent predictor of all-cause mortality in patients with aortic stenosis[J]. Eur Heart J Cardiovasc Imaging, 2012, 13(10):827-833.
[30] Garg V, Ho JK, Vorobiof G. Changes in myocardial deformation after transcatheter and surgical aortic valve replacement[J]. Echocardiography, 2017, 34(4):603-613.
[31] Rodríguez-Palomares JF, Dux-Santoy L, Guala A, et al. Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease[J]. J Cardiovasc Magn Reson, 2018, 20(1):28.
[32] Hope MD, Hope TA, Meadows AK, et al. Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns[J]. Radiology, 2010, 255(1):53-61.
[33] 张超越, 张楠, 李宇, 等. 主动脉瓣二瓣畸形升主动脉血流动力学变化的4D磁共振血流动力学对比研究[J]. 心肺血管病杂志, 2017, 36(7):564-568.
[34] Trauzeddel RF, Löbe U, Barker AJ, et al. Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement[J]. Intl J Cardiovasc Imaging, 2016, 32(3):461-467.

备注/Memo

备注/Memo:
基金项目:上海市浦东新区卫生系统重点学科群建设资助(PWZxq2017-05)
作者单位:200120 上海,同济大学附属东方医院心内科
通信作者:张奇,Email:zhangqnh@hotmail.com
更新日期/Last Update: 2019-09-27