|本期目录/Table of Contents|

[1]高洁,王晓群,李畅,等.心房螺旋电极导线临床应用的可行性和安全性[J].国际心血管病杂志,2017,06:360-364.
 GAO Jie,WANG Xiaoqun,LI Chang,et al.The clinical feasibility and safety of active fixation atrial leads[J].International Journal of Cardiovascular Disease,2017,06:360-364.
点击复制

心房螺旋电极导线临床应用的可行性和安全性(PDF)

《国际心血管病杂志》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2017年06期
页码:
360-364
栏目:
临床研究
出版日期:
2017-11-25

文章信息/Info

Title:
The clinical feasibility and safety of active fixation atrial leads
作者:
高洁王晓群李畅王义龙顾刚
200025 上海交通大学医学院附属瑞金医院心脏科
Author(s):
GAO Jie WANG Xiaoqun LI Chang WANG Yilong GU Gang
Department of Cardiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
关键词:
心脏起搏器 心房螺旋电极 被动固定电极 起搏参数
Keywords:
Cardiac pacemaker Active fixation atrial leads Passive fixation atrial leads Pacing parameters
分类号:
-
DOI:
10.3969/j.issn.1673-6583.2017.06.011
文献标识码:
A
摘要:
目的:探讨心房起搏使用螺旋电极导线(主动固定电极导线)的可行性和安全性。方法:入选2015年11月至2016年6月在瑞金医院心脏科置入埋藏式人工心脏双腔起搏器的患者,共109例。根据心房电极导线的类型分为螺旋电极组(n=68)和被动固定电极组(n=41),观察两组在置入术中即刻和术后1、3个月的起搏参数变化及并发症等情况。结果:螺旋电极组术中即刻起搏阈值明显高于被动固定电极组[(1.12±0.40)V对(0.67±0.28)V,P<0.0
Abstract:
Objective:To explore the feasibility and safety of active fixation atrial leads for atrial pacing.Methods:From November 2015 to June 2016, a total of 109 consecutive patients undergoing implantation of dual-chamber pacemaker in Ruijin hospital were retros

参考文献/References

[1] Mond HG. The world survey of cardiac pacing and cardioverter-defibrillators: lessons learnt[J]. J Interv Card Electrophysiol, 2006, 17(3):211-214.
[2] Mond HG, Irwin M, Ector H, et al. The world survey of cardiac pacing and cardioverter-defibrillators: calendar year 2005 an International Cardiac Pacing and Electrophysiology Society(ICPES)project[J]. Pacing Clin Electrophysiol, 2008, 31(9):1202-1212.
[3] Occhetta E, Bortnik M, Marino P. Future easy and physiological cardiac pacing[J]. World J Cardiol, 2011, 3(1):32-39.
[4] Pecha S, Kennergren C, Yildirim Y, et al. Coronary sinus lead removal: acomparison between active and passive fixation leads[J].PLoS One, 2016, 11(4):e0153651.
[5] Crossley GH, Sorrentino RA, Exner DV, et al. Extraction of chronically implanted coronary sinus leads active fixation vs passive fixation leads[J]. Heart Rhythm, 2016, 13(6):1253-1259.
[6] Maytin M, Carrillo RG, Baltodano P, et al. Multicenter experience with transvenous lead extraction of active fixation coronary sinus leads[J]. Pacing Clin Electrophysiol, 2012, 35(6):641-647.
[7] Hidden-Lucet F, Halimi F, Gallais Y, et al. Low chronic pacing thresholds of steroid-eluting active-fixation ventricular pacemaker leads: a useful alternative to passive-fixation leads[J]. Pacing Clin Electrophysiol, 2000, 23(11 Pt 2):1798-1800.
[8] Ellenbogen KA, Hellkamp AS, Wilkoff BL, et al. Complications arising after implantation of DDD pacemakers: the MOST experience[J]. Am J Cardiol, 2003, 92(6):740-741.
[9] Luria D, Bar-Lev D, Gurevitz O, et al. Long-term performance of screw-in atrial pacing leads: a randomized comparison of J-shaped and straight leads[J]. Pacing Clin Electrophysiol, 2005, 28(9):898-902.
[10] Kistler PM, Liew G, Mond HG.Long-term performance of active-fixation pacing leads: a prospective study[J]. Pacing Clin Electrophysiol, 2006, 29(3):226-230.
[11] Liu L, Tang J, Peng H, et al. A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads[J]. Sci Rep, 2015, 5:7662.
[12] Kistler PM, Kalman JM, Fynn SP, et al. Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads[J]. Pacing Clin Electrophysiol, 2005, 28(9):903-909.
[13] Kashiwase K, Kobayashi H, Hirata A, et al. Acute changes in the pacing threshold after lead implantation. Comparison between retractable and sweet-tip active-fixation leads[J]. Int Heart J, 2012, 53(2):108-112.
[14] Mond HG, Helland JR, Stokes K, et al. The electrode-tissue interface: the revolutionary role of steroid-elution[J]. Pacing Clin Electrophysiol, 2014, 37(9):1232-1249.
[15] Mond HG, Hua W, Wang CC.Atrial pacing leads: the clinical contribution of steroid elution[J]. Pacing Clin Electrophysiol, 1995, 18(9 Pt 1):1601-1608.
[16] Luria DM, Feinberg MS, Gurevitz OT, et al. Randomized comparison of J-shaped atrial leads with and without active fixation mechanism[J]. Pacing Clin Electrophysiol, 2007, 30(3):412-417.
[17] Krupienicz A, Karczmarewicz S, Marciniak W, et al. Passive-fixation J-shaped versus straight leads in atrial position: comparison of efficacy and safety[J]. Pacing Clin Electrophysiol, 2000, 23(12):2068-2072.

备注/Memo

备注/Memo:
通信作者:顾刚,Email:gugang@medmail.com.cn
更新日期/Last Update: 2017-12-10